济南科邦机械设备有限公司您身边的济南空压机厂家!
18765879198

首页>企业新闻
空压机停机怎么处理?
Time:2018-12-20 15:36:47       来源:http://www.jnkbjx.com/      

(1)制冷剂缺乏或过多,请补漏抽真空,加足制冷剂或放出多余的制冷剂。

(1) Refrigerant shortage or excess, please fill the leak and vacuum, add enough refrigerant or release excess refrigerant.
(2)毛细管组件(含过滤器)堵塞,吸气温度升高,请替换毛细管组件。
(2) The capillary assembly (including filter) is blocked and the temperature of suction rises. Please replace the capillary assembly.
(3)四通阀内部漏气,构成误动作,承认损坏后更新。
(3) The internal leakage of the four-way valve, which constitutes a misoperation, is renewed after admitting damage.
(4)空压机自身毛病,如短路、断路、碰壳通地等,查看承认后替换空压机。
(4) The air compressor's own faults, such as short circuit, circuit break, encountering the shell to the ground, etc., should be replaced after checking and admitting.
(5)保护继电器自身毛病,请用万用表查看在空压机不外热时其触点是否导通,若不导通替换新的保护器。当替换5528、5532空压机时,需查看发动电容和发动继电器(如其中之一损坏,则必需两者一起替换)。
济南空压机
(5) Protecting relay has its own faults. Please use the multimeter to check whether the contacts are on when the air compressor is not hot outside, and replace the new protector if not. When replacing 5528 and 5532 air compressors, check the starting capacitance and relay (if one of them is damaged, both must be replaced together).
(6)高压压力过高,压力继电器动作,请剖析原因,针对情况予以扫除。
(6) High voltage pressure, pressure relay action, please analyze the reasons, according to the situation to be cleaned.
(7)冷凝器透风不良或气流短路,请扫除室外侧的障碍物,清洗冷凝器。
(7) Condenser is not ventilated well or short-circuited. Clean the outside obstacles and condenser.
(8)体系混有不凝液气体(如空气等),请抽真空重新灌注。
(8) The system is coagulated with non-condensate gases (e.g. air), so vacuum refilling is required.
空压机工作电流过大,请查明原因予以扫除。
The working current of air compressor is too large. Please find out the reason and clean it up.
室外机组环境温渡过高,请阔别热源,避免日晒。
The ambient temperature of outdoor units is too high. Please keep away from heat sources and avoid sunshine.
空压机卡缸或抱轴。可用橡胶锤或铁锤垫上木块敲击振荡空压机外壳,或选用并联电容、放氟空载的办法,或许使得空压机发动工作,但若无效则应替换空压机。
Air compressor jam or hold axle. The rubber hammer or hammer cushion can be used to knock on the shell of the oscillating air compressor, or the parallel capacitor can be used to discharge fluorine without load. Perhaps the air compressor can start work, but if it is ineffective, the air compressor should be replaced.